Current Mark Displays

Models:

CRM3000-50-I

CRM3000-50-R

1. Provide power to the unit.

2. Determine desired current level to activate alarm

3. Press and hold alarm button for two seconds and release

4. LCD display blinks either the last alarm setting or “Aoff”.

(Unit is factory set in “Aoff” mode)

5. Depress and release alarm button until desired set-point is reached

6. Press and hold alarm button for two seconds

7. Set-point is stored in memory and unit returns to normal operation

8. To deactivate alarm, press and hold alarm button for two seconds in “Aoff” mode

1

2

3

Red

- Alarm: Active High, 3.3 VDC (1mA Max.)

BLACK - Solid State Switch -NPN (20mA Max., 200 VDC)

Green

- Ground

ALARM PROGRAMMING AND OPERATING INSTRUCTIONS

CRM3000 ALARM CABLE & PIN CONNECTOR (Optional)

CRM3000-CBL-36

CRM3000 Alarm Cable Assembly 36” Lead

CRM3000 CABLE ASSEMBLY CONNECTION DIAGRAM

ED

- Alarm Active High 3.3 Vdc (1mA Max)

K - Solid State Switch - NPN (20mA Max, 200 Vdc)

REEN

- Ground