64
Relays, Switches, & Sensors
D
3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
Web:
http://www.crmagnetics.comE-mail:
sales@crmagnetics.comThe Professional
Energy Monitoring
Company
ISO 9001:2008QualityManagementSystem
M N TI
Direct Current Sensing Relay
CR5395 Series
VOLTAGE
LOAD TYPE
240 VAC
240 VAC
N.O. CONTACT
N.C. CONTACT
Resistive
Motor
20A
2HP
10A
1/2 HP
125 VAC
28 VDC
Motor
Resistive
1HP
20A
1/4 HP
10A
The
CR5395
Series, Direct Current Sensing Relay provides a
precision and cost effective method for monitoring Direct Cur-
rent. Magnetic Modulator Technology is utilized for the current
sensing to provide a stable and highly repeatable current trip.
The current-carrying wire is routed through the opening extend-
ing through the top of the case. When current reaches the level
set by the trip point adjustment, the relay trips and starts the ad-
justable timer. After the timer cycles the electromechanical relay
energizes.
Applications
DC motor drives
Battery Chargers
Power Supply Management
Uninterruptible Power Systems
Motor Application
Features
Variable Trip Point and Time Delay
Bi-polar
Monitors Currents from 1.0 ADC to 100 ADC
Electrical Isolation Between Circuits
Output Relay Rated up to 20 Amps
LED Trip Status Indicator
Dead Band Prevents Relay Chatter
Calibrated Dial
External Current Transformers Available
Specifications
Mounting:
3/16” dia. clearance holes on 1
15/16
”by 2
15/16
”centers
Environmental:
Operating Temperature: -30° C to +70° C
Storage Temperature: -55° C to +85°
0-95% RH, Non-condensing
Input Supply Power:
Typical 80mA
Max 100mA
Sensed Current: Max. Continuous: 200% Full Scale
Altitude: 2000 meters max.
(Contact factory for High Altitude applications)
Weight 0.5 LBS.
Regulatory Agencies
OUTPUT OPTIONS
The Relay is available with three different output
configurations, electromechanical relay, op-
toisolated NPN transistor or ZeroCrossing op-
toisolated triac. Specify desired selection in part
number.
DC SWITCHING (-NPN)
Vce (full off): 30 VDC max.
Isink (full on): 120 mADC max.@ rated full-on
Vce (full on): 1.5 VDC @ 120 mADC Isink
Off state leakage current: 5ua @ 30 VDC
(typical)
Terminals: 2
1/4”
Male QC
RELAY (-ELR)
Arrangement: 1 Form C (SPDT)
Contact Material: Silver-cadmium oxide
Terminals: 3
1/4”
Male QC
Mechanical Life: 10 million operations,
typ.@ rated load
Electrical Life: 100,000 operations,
typ. @ rated load
Initial Contact Resistance:
50 milliohms max. @ 500 mA, 12 VDC
Contact Rating: UL508/873 & CSA
AC SWITCHING (-TRC)
Off state voltage: 240 VAC RMS max.
Minimum switch voltage: 24 VAC RMS
On state current: 500 mA RMS max. continuous
Switching mode: Zero Crossing
Off state leakage: 60 ua @ 240 VAC max.
Terminals: 2 @ 1/4” Male QC
E234389