Direct Current Sensing Relay

CR5395 Series

OUTLINE DRAWING

A

B

C

D

Remote Current Transformers CRDCS - Series

Relays, Switches, & Sensors

D

3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119

Web:

http://www.crmagnetics.com

E-mail:

sales@crmagnetics.com

The Professional

Energy Monitoring

Company

ISO9001:2008QualityManagementSystem

M N TI

SUPPLY VOLTAGE

ACV

- 85 to 265 VAC/VDC

24D

- 24 VDC

All supply voltage tolerances

are ± 10 %

Top view of Current Sensing Relay

Shown with Remote Current

Transformer Option (-R)

PART NUMBER

CR5395

-

-

-

-

-

-

-

CRDCS

A B C D

-100

2.88

73.16

1.60

40.58

12

304.8

0.79

20.07

-200

3.25

82.55

1.75

44.45

12

304.8

0.82

20.83

TRIP STATUS

EH

- Energized on High, trips

when sense current is above trip

point and returns to non-trip

status when sense current is

below the trip point.

EL

- Energized on Low, trips

when sense current is below trip

point and returns to non-trip

status when sense current is

above the trip point.

LH

- Latch on High, trips when

sense current is above trip point

and remains tripped until

supply power is removed.

LL

- Latch on Low, trips when

sense current is below trip point

and remains tripped until supply

power is removed.

TRIP RANGE

110

- 1.0 to 10 ADC

330

- 3.0 to 30 ADC

660

- 6.0 to 60 ADC

101

- 10 to 100 ADC

The trip ranges shown are for

one wire pass through the

window opening. The trip range

may be proportionally lowered

with additional wire passes

through the window.

TRIP POINT DIAL

CD

- Calibrated Dial

FP

- Fixed Trip Point

(Specify value of fixed

trippoint with order)

3

5

10

15

30

20

CURRENTTRIP

D

25

No adjustment

dial provided with

the fixed set

point option

- CD - FP

-3.30 trip range shown

OUTPUT OPTIONS

ELR

Electromechanical

Relay

NPN

Optoisolated

NPN Transistor

TRC

Optoisolated

Triac, Zero Crossing

NC NO COM

-

+

+

TRIP ON DELAY

A

- .5 to 6 Sec.

B

- 2 to 25 Sec.

C

- .1 to 1 Sec.

X

- none

Time-on delay is the time from when the relay trips to

when the output energizes. The ranges are

guaranteed minimum, actual range may be slightly

greater.

I

- INTERNAL TRANSFORMER

R1

- REMOTE TRANSFORMER

w/ CRDCS-100

(1.60” window diameter)

R2

- REMOTE TRANSFORMER

w/ CRDCS-200

(1.75” window diameter)

Example Part Numbers:

CR5395-EH-ACV-110-CD-ELR-I (Relay with CT on board)

CR5395-EL-24D-330-CD-NPN-R1 (Relay with external CRDCS-100)